Model | TBK 25-100 |
---|---|
Fuel Type | Solid Fuel (Coal) |
Working Pressure (Bar) | 3 Bar |
Capacity (kW) | 29-116 kW |
Parameters | Unit | TBK Sliced | |||||
Rated Heat Power (Coal) | kW | 29 | 46 | 70 | 93 | 116 | |
kCal/h | 25000 | 40000 | 60000 | 80000 | 100000 | ||
Fuel Capacity | Lt | 71 | 93 | 134 | 153 | 172 | |
Water Volume | Lt. | 66 | 77 | 139 | 159 | 179 | |
Operating Pressure | Bar | 3 | |||||
Test Pressure | Bar | 4,5 | |||||
Flue Diameter | mm | Ø127 | Ø160 | ||||
Electrical Connection | V/Hz | 230/50 | |||||
A | mm | 520 | 520 | 640 | 640 | 640 | |
B | mm | 730 | 730 | 850 | 850 | 850 | |
C | mm | 1400 | 1400 | 1575 | 1575 | 1575 | |
D | mm | Ø127 | Ø160 | ||||
E | mm | 570 | 670 | 770 | 870 | 970 | |
F | mm | 670 | 770 | 870 | 970 | 1070 | |
G (Filling - Unloading) | R | ½ | ½ | ½ | ½ | ½ | |
H (Radiator Return) | R | 1 | 1 | 1 ¼ | 1 ½ | 1 ½ | |
I (Expansion Return) | R | ¾ | 1 | 1 | 1 ¼ | 1 ¼ | |
J (Expansion Departure) | R | ¾ | 1 | 1 | 1 ¼ | 1 ¼ | |
K (Radiator Departure) | R | 1 | 1 | 1 | 1 ½ | 1 ½ | |
L (Combustion Chamber Height) | mm | 425 | 425 | 395 | 395 | 395 | |
K (Combustion Chamber Depth) | mm | 525 | 625 | 725 | 825 | 925 |